13B-100
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$072.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
DF034
CONTINUED 2
CC.0NOTESNone.
Check the conformity of fuse: FM13 (70A) or FM14 (70A) or FM3 (30A) (see MR364 (Mégane II ph2), MR370
(Scénic II ph2), MR 395 (Laguna II ph2), 402 (Vel Satis ph2), 405 (Espace IV ph2) Mechanical, 81C, Fuses,
Fuses: List and location of components).
Check the condition of the thermoplunger 3 relay mounting connector on the engine fuse box or additional heater
interface unit (see Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II
ph2, Scénic II ph2, component code 1069 or 1550).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the conformity of the thermoplunger 3 relay (relay removed):
–Insulation between components BP9 and 3JAC or 3JC of component 1069 or 1550.
– Measure the resistance between connections 3FB and 3JAB of component 1069 or 1550.
Replace the relay if its resistance is greater than 1 kΩ or less than 6 Ω.
Replace the unit if the resistance is less than 450 Ω (M9R721).
Check the insulation to earth of the following connection:
•3JAB between components 120 and 1069 or 1550.
Check the + 12 V after relay supply to the thermoplunger 3 relay mounting on the following connection:
•3FB
of component 1069 or 1550.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.

Page 101 of 510

13B-101
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$072.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
DF034
CONTINUED 3
1.DEFNOTESSpecial notes:
This fault appears when the computer control section has
overheated.
Check the conformity of fuse: FM13 (70A) or FM14 (70A) or FM3 (30A) (see MR364 (Mégane II ph2), MR370
(Scénic II ph2), MR 395 (Laguna II ph2), 402 (Vel Satis ph2), 405 (Espace IV ph2) Mechanical, 81C, Fuses,
Fuses: List and location of components).
Check the condition of the thermoplunger 3 relay mounting connector on the engine fuse box or additional heater
interface unit (see Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II
ph2, Scénic II ph2, component code 1069 or 1550).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the conformity of the thermoplunger 3 relay (relay removed):
–Insulation between components BP9 and 3JAC or 3JC of component 1069 or 1550.
– Measure the resistance between connections 3FB and 3JAB of component 1069 or 1550.
Replace the relay if the resistance is greater than 1 kΩ or less than 6 Ω.
Check the absence of interference resistance of the following connection:
•3JAB between components 120 and 1069 or 1550.
Also check the insulation on the following connections:
Check the + 12 V after relay feed to the "thermoplunger 3'' relay mounting on the following connection:
•3FB of component 1069 or
1550.
Check the + 12 V after fuse battery supply to the thermoplunger 3 relay mounting on the following connection:
•BP9 of component 1069 or 1550.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.

Page 132 of 510

13B-132
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$072.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
EDC16CP33
Program No.: C4
Vdiag No.: 18, 1C, 20, 24,
26, 28, 54, 58, 5C, 60, 62
DF086
PRESENT
OR
STOREDCOOLANT PUMP RELAY CONTROL CIRCUITCO: Open circuit
CC.0: Short circuit to earth
CC.1: Short-circuit on +12 volts.
1.DEF: Internal electronic fault
NOTESConditions for applying the fault finding procedure to a stored fault:
If the fault becomes present after:
– the ignition is switched on.
– starting the engine,
– a road test.
Special notes:
The control relay is located in the engine compartment connection unit.
Use bornier Elé. 1681 for all operations on the engine management computer
connectors.
Use the Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV
ph2, Mégane II ph2, Scénic II ph2.
CO
NOTESNone.
Check the condition of the coolant pump relay mounting connector on the engine fuse box (see Wiring Diagram
Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code
597).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the conformity of the coolant pump relay (relay removed):
•Insulation between connections 3FB and 3VH of component 573.
• Measure the resistance between connections 3AAZ and 3FB of component 573.
Replace the relay if the resistance of the coolant pump relay is greater than 1 kΩ or less than 6 Ω.
EDC16CP33_V18_DF086 / EDC16CP33_V1C_DF086 / EDC16CP33_V20_DF086 / EDC16CP33_V24_DF086 / EDC16CP33_V26_DF086 /
EDC16CP33_V28_DF086 / EDC16CP33_V54_DF086 / EDC16CP33_V58_DF086 / EDC16CP33_V5C_DF086 / EDC16CP33_V60_DF086 /
EDC16CP33_V62_DF086

Page 133 of 510

13B-133
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$072.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
EDC16CP33
Program No.: C4
Vdiag No.: 18, 1C, 20, 24,
26, 28, 54, 58, 5C, 60, 62
DF086
CONTINUED 1
Check the continuity of the following connections:
•3AAZ between components 120 and 573,
•3VH between components 573 and 369,
•M between components 369 and the vehicle earth.
Check the + 12 V after relay supply to the coolant pump relay:
•3FB of component 573.
If the connection or connections are faulty and if there is a repair method (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
CC.1
NOTESNone.
Check the condition of the coolant pump relay mounting connector on the engine fuse box (see Wiring Diagram
Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code
597).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the conformity of the coolant pump relay (relay removed):
•Insulation between connections 3FB and 3VH of component 573.
• Measure the resistance between connections 3AAZ and 3FB of component 573.
Replace the relay if the resistance of the coolant pump relay is greater than 1 kΩ or less than 6 Ω.
Check the insulation from + 12 V of the following connections:
•3AAZ between components 120 and 573,
•3VH between components 573 and 369.
If the connection or connections are faulty and if there is a repair method (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.

Page 134 of 510

13B-134
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$072.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
EDC16CP33
Program No.: C4
Vdiag No.: 18, 1C, 20, 24,
26, 28, 54, 58, 5C, 60, 62
DF086
CONTINUED 2
CC.0NOTESNone.
Check the condition of the coolant pump relay mounting connector on the engine fuse box (see Wiring Diagram
Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code
597).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the conformity of the coolant pump relay (relay removed):
•Insulation between connections 3FB and 3VH of component 573.
• Measure the resistance between connections 3AAZ and 3FB of component 573.
Replace the relay if the resistance of the coolant pump relay is greater than 1 kΩ or less than 6 Ω.
Check the insulation to earth of the following connections:
•3AAZ between components 120 and 573,
•3VH between components 573 and 369.
Check the + 12 V after relay supply to the coolant pump relay on the following connection:
•3FB of component 573.
If the connection or connections are faulty and if there is a repair method (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.

Page 135 of 510

13B-135
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$072.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
EDC16CP33
Program No.: C4
Vdiag No.: 18, 1C, 20, 24,
26, 28, 54, 58, 5C, 60, 62
DF086
CONTINUED 3
1.DEFNOTESSpecial note:
This fault appears when the computer control section has
overheated.
Check the condition of the coolant pump relay mounting connector on the engine fuse box (see Wiring Diagram
Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code
597).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the conformity of the coolant pump relay (relay removed):
•Insulation between connections 3FB and 3VH of component 573.
• Measure the resistance between connections 3AAZ and 3FB of component 573.
Replace the relay if the resistance of the coolant pump relay is greater than 200 Ω or less than 20 Ω.
Check the absence of interference resistance of the following connection:
•3AAZ between components 120 and 573.
Check the + 12 V after relay supply to the coolant pump relay on the following connection:
•3FB of component 573.
Check the + 12 V battery supply to the coolant pump relay on the following connection:
•3FB of component 573.
If the connection or connections are faulty and if there is a repair method (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
If the fault is still present, contact the Techline.

Page 145 of 510

13B-145
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$073.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF151
STOREDMAIN RELAY CIRCUIT1.DEF: Relay cut off too soon
2.DEF: Relay cut off too late
NOTESSpecial notes:
The level 1 warning light is on.
Use the Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV
ph2, Mégane II ph2, Scénic II ph2.
IMPORTANT:
For Mégane II ph2 and Scénic II ph2, the injection supply relay is located on the UPC.
For Laguna II ph2 and Espace IV ph2, the injection supply relay is located on the
engine fuse and relay box.
1.DEF
NOTESNone.
Check the condition of the injection supply relay mounting connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 983).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the tightness and the condition of the "+ " and "-" battery terminals.
Check the conformity of the main relay (relay removed) (Laguna II ph2 and Espace IV ph2):
•Insulation between connections 3FB and BP37 or 3MV of component 983.
• Measure the resistance between connections3AA and BP37 of component983.
(see Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II
ph2, Component code 983).
Replace the relay if its resistance is less than 6 Ω or greater than 1 kΩ.
EDC16CP33_V18_DF151M / EDC16CP33_V1C_DF151M / EDC16CP33_V54_DF151M / EDC16CP33_V20_DF151M /
EDC16CP33_V58_DF151M / EDC16CP33_V5C_DF151M / EDC16CP33_V24_DF151M / EDC16CP33_V04_DF151M /
EDC16CP33_V08_DF151M / EDC16CP33_V44_DF151M / EDC16CP33_V4C_DF151M / EDC16CP33_V34_DF151M /
EDC16CP33_V38_DF151M / EDC16CP33_V74_DF151M / EDC16CP33_V28_DF151M / EDC16CP33_V62_DF151M/
EDC16CP33_V26_DF151M / EDC16CP33_V60_DF151M
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74

Page 255 of 510

13B-255
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF997
PRESENT
OR
STOREDCONTROL UNIT -> THERMOPLUNGERS CONNECTION
1.DEF: Signal incoherent
NOTESConditions for applying the fault finding procedure to a stored fault:
the fault is declared present after the engine starts.
Special notes:
If the fault is present:
The engine performance is impaired during the particle filter regeneration phase.
Check the condition of the thermoplunger 1, 2, 3 relay mounting connector on the engine fuse box or additional
heater interface unit (see Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV ph2,
Mégane II ph2, Scénic II ph2, component code 1067, 1068, 1069 or 1550).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
Check the condition of the thermoplunger connectors (see Wiring Diagram Technical Note, Laguna II ph2, Vel
Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component codes 898, 1072, 1073, 1074).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the conformity of the thermoplunger 1, 2, 3 relay (relay removed) or the additional heater interface unit:
– Check the insulation between the following connections:
•BP9 and 3JB of component 1067 or 1550.
•BP91 and 3JAD or 3JD and 3JAC of component 1068 or 1550.
•BP9 and 3JAC or 3JC of component 1069 or 1550.
If the connection or connections are faulty and if there is a repair method (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
Check the continuity of the following connections:
•3JAC or 3JC between component
1069 or 1550,
•3JAD or 3JD and 3JAC between component 1068 or 1550,
•3JA between component 1067 or 1550.
If the connection or connections are faulty and if there is a repair method (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
EDC16CP33_V18_DF997 / EDC16CP33_V1C_DF997 / EDC16CP33_V54_DF997 / EDC16CP33_V20_DF997 / EDC16CP33_V58_DF997 /
EDC16CP33_V5C_DF997 / EDC16CP33_V24_DF997 / EDC16CP33_V28_DF997 / EDC16CP33_V62_DF997 / EDC16CP33_V26_DF997 /
EDC16CP33_V60_DF997
EDC16CP33
Program No.: C4
Vdiag No.: 18, 1C, 20, 24,
26, 28, 54, 58, 5C, 60, 62

Page 265 of 510

13B-265V12 MR-372-J84-13B300$101.mif
DIESEL INJECTION
Fault finding – Interpretation of statuses13B
ET001
CONTINUED
If the ignition is not switched on, status ET001 should be ABSENT.
As soon as the ignition is switched on, the computer should be supplied with power. Status ET001 becomes
PRESENT.
If this status remains locked on ABSENT, follow the procedure below:
– Check the condition of fuse FM3 (30A) in the engine fuse and relay box (see MR 395 (Laguna II ph2), 405
(Espace IV ph2) Mechanical, 81C, Fuses, Fuses: List and location of components).
– Check the condition of fuse F18 (15A) in the Protection and Switching Unit (UPC) (see MR364 (Mégane II ph2),
MR370 (Scénic II ph2) Mechanical, 81C, Fuses, Fuses: List and location of components).
Check the continuity and absence of interference resistance on the following connection:
•3AA between components 120 and 983 or 1337.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
If the fault is still present, contact the Techline.
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.

Page 267 of 510

13B-267V12 MR-372-J84-13B300$101.mif
DIESEL INJECTION
Fault finding – Interpretation of statuses13B
ET007PRE-POSTHEATING UNIT CONTROL
STATUS
DEFINITIONACTIVE: when the heater plugs are activated according to the engine coolant
temperature.
INACTIVE: after the engine has been running for a certain period
In the event of a fault, consult the interpretation of fault DF017 Preheating unit
control circuit.
NOTESSpecial notes:
This status is specific to slow heater plugs (black ring).
Conformity check with engine stopped and ignition on.
"ACTIVE"When the ignition is switched on, status ET007 should be ACTIVE for a time that varies
according to the engine coolant temperature. Both the relay and the heater plugs are
supplied.
After starting, the status should remain ACTIVE for a time that varies according
to the engine temperature. This is the postheating phase.
If ET007 is INACTIVE when the ignition is switched on, check:
– Supply fuse FM12 (70A) of component 597 (engine fuse and relay box) or F2 (70A)
of component 777 for Mégane II and Scénic II
–The supply to the heater plugs after relay actuation, and the connections of the
heater plugs.
Important: on this engine, the plug supply voltage is variable.
– Check the continuity and absence of interference resistance of the following
connections:
•37AB between components 257 and 683,
•37AA between components 257 and 680,
•37Z between components 257 and 681,
•37AC between components 257 and 682.
If the connection or connections are faulty and there is a repair procedure (see
Technical Note 6015A, Electrical wiring repair, Wiring: Precautions for repair),
repair the wiring, otherwise replace it.
EDC16CP33_V18_ET007 / EDC16CP33_V1C_ET007 / EDC16CP33_V54_ET007 / EDC16CP33_V20_ET007 / EDC16CP33_V58_ET007 /
EDC16CP33_V5C_ET007 / EDC16CP33_V24_ET007 / EDC16CP33_V04_ET007 / EDC16CP33_V08_ET007 / EDC16CP33_V44_ET007 /
EDC16CP33_V4C_ET007 / EDC16CP33_V34_ET007 / EDC16CP33_V38_ET007 / EDC16CP33_V74_ET007 / EDC16CP33_V28_ET007 /
EDC16CP33_V26_ET007
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 74

Page:   < prev 1-10 11-20 21-30 next >